#13831 - 09/19/17 07:43 AM DM8000HD restarting uncontrolled
knet Offline
VIP Japhar
stranger

Registered: 09/06/17
Posts: 8
Lately my DM8000 (image OpenPLi 2.1-Japhar-SIM) developed a nasty habit of restarting uncontrolled, without my command. It usually happens after I switch it on (from stand by). After the restart it works normally, no matter how long. It also means I can´t use the timer to set up recordings.

Top
#13833 - 09/19/17 01:10 PM Re: DM8000HD restarting uncontrolled [Re: knet]
Admin Online   content
Japhar Member
Carpal Tunnel

Registered: 10/19/10
Posts: 10097
Did you checked the Capacitors, the 7 that generally have to be replaced after few years of use, if the power supply / DM8000HD is a clone ?

Read here : http://www.ourdreambox.com/ubbthreads.php?ubb=showflat&Number=1592#Post1592

Admin
_________________________

Top
#13895 - 09/25/17 02:37 PM Re: DM8000HD restarting uncontrolled [Re: Admin]
knet Offline
VIP Japhar
stranger

Registered: 09/06/17
Posts: 8
The capacitors you mean are the 7 largest?

4 1000uF 35V
2 220uF 250V
1 2200uF 10V

220uF and 2200uF measuring ok. But not the four 1000uF.

Top
#13896 - 09/25/17 02:47 PM Re: DM8000HD restarting uncontrolled [Re: knet]
Admin Online   content
Japhar Member
Carpal Tunnel

Registered: 10/19/10
Posts: 10097
At least the 4 x 1000uF 35V yes, and often the small one, 47uF/50V or 22uF/50V (C109)

Yes, the 2 big are not alway necessary to replace, 2 big (100uF/400V or 220uF/250V depending of your PSU version)

Admin
_________________________

Top


Moderator:  storm_breaker, Toysoft 
New Topics
Dreambox 7020 v2 software not working
by OMEGA
03/09/26 06:55 PM
Adding a Reset Button
by Atlas Informatik
03/02/26 12:33 PM